Material Status •Commercial: Active
Literature 1 •Technical Datasheet (English)
Processing Method •Injection Molding
Physical Dry Conditioned Unit Test Method
Specific Gravity 1.14 -- g/cm³ ASTM D792, ISO 1183
Molding Shrinkage - Flow 1.3 to 2.0 -- % Internal Method
Water Absorption
Equilibrium -- 2.5 % ASTM D570
Equilibrium, 23°C, 50% RH -- 2.5 % ISO 62
Hardness Dry Conditioned Unit Test Method
Rockwell Hardness ASTM D785, ISO 2039-2
M-Scale 80 55
R-Scale 120 108
Mechanical Dry Conditioned Unit Test Method
Tensile Modulus (23°C) 3000 1200 MPa ISO 527-2
Tensile Stress
Yield, 23°C 82.0 52.0 MPa ISO 527-2
-- 79.0 57.0 MPa ASTM D638
Tensile Strain
Yield, 23°C 4.0 24 % ISO 527-2
Break 50 250 % ASTM D638
Break, 23°C -- > 100 % ISO 527-2
Flexural Modulus
-- 2800 1200 MPa ASTM D790
23°C 2700 1100 MPa ISO 178
Flexural Strength
-- 118 54.0 MPa ASTM D790
23°C 113 42.0 MPa ISO 178
Taber Abrasion Resistance -- 7.00 mg ASTM D1044
Impact Dry Conditioned Unit Test Method
Charpy Notched Impact Strength 6.0 15 kJ/m² ISO 179
Charpy Unnotched Impact Strength No Break No Break ISO 179
Notched Izod Impact 39 150 J/m ASTM D256
Thermal Dry Conditioned Unit Test Method
Deflection Temperature Under Load
0.45 MPa, Unannealed 230 -- °C ASTM D648
0.45 MPa, Unannealed 192 -- °C ISO 75-2/B
1.8 MPa, Unannealed 70.0 -- °C ASTM D648
1.8 MPa, Unannealed 68.0 -- °C ISO 75-2/A
CLTE - Flow 0.000080 -- cm/cm/°C ASTM D696, ISO 11359-2
Specific Heat 1670 -- J/kg/°C No Standard
Thermal Conductivity 0.20 -- W/m/K No Standard
Electrical Dry Conditioned Unit Test Method
Surface Resistivity 1.0E+13 -- ohm IEC 60093
Volume Resistivity (23°C) 1.0E+14 -- ohm·cm IEC 60093
Electric Strength 20 -- kV/mm IEC 60243-1
Comparative Tracking Index (3.00 mm) 600 -- V IEC 60112
Flammability Dry Conditioned Unit Test Method
Flame Rating UL 94
0.794 mm V-2 --
1.59 mm V-2 --
Injection Dry Unit
Drying Temperature 80.0 to 90.0 °C
Drying Time 2.0 to 3.0 hr
Processing (Melt) Temp 270 to 290 °C
Mold Temperature 75.0 to 85.0 °C